PT. Bopana Arga Prima Jaya

sql
SK SATO Cat.No.8152-50 EM Digital Panel Meter Model SK-EM-01
Hover to Zoom

Update Terakhir
31 Jan 2020
Negara Asal
Japan
Pembelian Min
1 Unit

Spesifikasi

SK SATO Cat.No.8152-50 EM Digital Panel Meter Model SK-EM-01
Features
  • Easy-to-read large bright LED display (height of character: 20mm)
  • Multiple inputs: Thermocouple, RTD and voltage
  • Compact (DIN ) size: 48×96mm
  • Suitable to connect with SK-8200 infrared thermometer and SK-RHC series transmitters.
  • Conform to RoHS directives
Specification
Display7 segment LED (height of character: 20mm)
ResolutionRefer to the table below
Power requirements100 to 240V AC ±10% (50/60Hz)
Power consumption11VA (100 to 240V AC)
MountingPush-in panel (One-touch mount)
Operating ambientTemperature:-10°C to 50°C,Humidity: lower than 90%rh(No condensing),Max. elevation: 2000m
Display accuracy±(0.3%FS+1dgit) within measuring range Thermocouple input: excluding cold junction temperature compensation accuracy. Thermocouple B: ±5%FS at lower than 400°C Thermocouple T,U: ±0.5%FS at -100°C to 0°C ±1%FS at lower than -100°C
Insulation resistanceBetween input/output terminal-power terminal: more than 500VDC 20MΩ Between input/output terminal-earth terminal: more than 500VDC 20MΩ
Dimensions/weight(W)96 × (H)48 × (D)111mm (inside100mm) approx. 250g

Table on Measuring range and codes

InputCodeRange(°C)Range(℉)Remarks
Multiple input (*1)ThermocoupleB010 to 18000 to 3300*2
R020 to 17000 to 3100
S030 to 17000 to 3100
K04-199.9 to 800.0-300 to 1500
050 to 12000 to 2200
E060 to 7000 to 1300
J070 to 6000 to 1100
T08-199.9 to 300.0-300 to 600*3
N090 to 13000 to 2300
U10-199.9 to 300.0-300 to 600*3
L110 to 6000 to 1100
WRe5-26120 to 23000 to 4200
R.T.D.Pt31-199.9 to 600.0-300 to 1100*4
32

-100.0 to 100.0

-150.0 to 200.0
JPt33-199.9 to 500.0-300 to 1000*4
34

-100.0 to 100.0

-150.0 to 200.0
Voltage0 to 10mV710.0 to 100.0 Scaling possible. Scaling setting range : -1999 to 9999Unit Span : 10 to 10000Unit
0 to 5V81
1 to 5V82
0 to 10V83

*1 Factory setting: K thermocouple (code 05: 0 to 1200°C) *2 Accuracy of B thermocouple at lower than 400°C: ±%FS *3 Accuracy of T, U thermocouple at -100 to 0°C: ±0.5%FS at lower than -100 : ±1%FS *4 Scale over occurs at at -240.0 at Pt (code 31) or JPt (code 33)
Alat Laboratorium Umum

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan