PT. Bopana Arga Prima Jaya

sql
 Koehler K47000 Autoignition Apparatus
Hover to Zoom

28 Jan 2020
United States
1 Pieces
IDR CALL

Spesifikasi

Spesifikasi Koehler K47000 Autoignition Apparatus

Test Method

Determines the lowest temperature at which the vapors of a liquid or solid chemical sample will self-ignite under prescribed laboratory conditions. The temperatures at which ‘cool flame’ and ‘hot flame’ ignitions occur, as evidenced by sudden temperature increases in the sample flask, are measured and recorded, and the delay time between introduction of the sample and ignition is timed.

Specification

Conforms to the specifications of: ASTM E659

Temperature Range: Ambient to 750°C

Temperature Control: digital setpoint solid state controller accurate to within ±1°C

Flask Temperature Display: 0-750°C, with four position selector switch

Features

  • Conforms to ASTM E659 specifications
  • Digital furnace temperature control
  • Digital flask temperature display

Description

Modified crucible furnace with digital thermocouple readout of flask temperature at prescribed points per ASTM specifications. Linearized analog output permits connection to a strip chart recorder or datalogging instrument. Furnace provides rapid response and ±1°C stability throughout the operating range from Ambient to 750°C. Cylindrical heating chamber provides excellent radial temperature uniformity. Furnace cover has ports for flask exterior thermocouples, and a borosilicate glass thermocouple tube is provided to assure correct positioning of the gas temperature thermocouple inside the test flask. Thermocouples plug directly into the furnace control unit for quick disconnection when removing the flask. A hinged holder in the cover facilitates handling of the test flask. Adjustable mirror permits safe viewing of the flask interior during testing. Control panel has temperature controls and digitalthermocouple readout with four-position selector switch.

Included Accessories

  • Borosilicate Test Flask, 500mL
  • Thermocouples (4)

Electrical Requirements

220-240V 50/60Hz, Single Phase, 7.7A

Additional Accessories

  • 362-001-000 Syringe, 1mL 
  • K470-0-1-14 Needle, 6", stainless steel 
  • K70015-1A Recorder, 115V/230V 50/60Hz 
  • 374-115-001 Hot Air Gun, 115V 60Hz - For purging product gases between tests 
  • 374-230-001 Hot Air Gun, 220-240 50/60Hz - For purging product gases between tests
  • 332-003-008 Quartz Test Flask, 500mL - For high temperature testing over 600°C
  • K470-0-1-8 Quartz Thermocouple Guide

Alat Laboratorium Umum


Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot