PT. Bopana Arga Prima Jaya

sql
Koehler K10290 Automatic Aniline Point Apparatus
Hover to Zoom

Update Terakhir
28 Jan 2020
Negara Asal
United States
Pembelian Min
1 Pieces

Spesifikasi

Spesifikasi Koehler K10290 Automatic Aniline Point Apparatus

Test Method

Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample or sample plus n-heptane are stirred together while being heated at a controlled rate. After the two phases become miscible, the mixture is cooled at a controlled rate and the temperature at which the two phases separate is the aniline point or mixed aniline point of the sample.

Specifications

Conforms to the specifications of: ASTM D611; IP 2; ISO 2977; DIN 51775; FTM 791-3601; NF M 07-021

Testing Range: 0 to 150°C (32 to 302°F)

Temperature Display: 0-999.9°C

Features

  • Conforms to ASTM D611 and related specifications
  • For samples ranging from clear to very dark
  • Temperature range 0°C to 150°C (32°F to 302°F)
  • Digital temperature display

Description

Performs aniline point and mixed aniline point determinations automatically by means of a modified thin film technique (ASTM D611 Method E). The sample-aniline mixture is directly heated by a platinum immersion heater and the aniline point is detected photoelectrically. Temperature is displayed on a large LED indicator. Built-in pressure regulator and solenoid valve permit the use of cooling air for quicker cooling cycles or to determine subambient aniline point temperatures. Aniline points as low as 0°C (32°F) can be determined with the use of refrigerated cooling air. Equipped with variable controls for heater, light source and stirrer speed. Cabinet exterior surfaces have a chemical resistant polyurethane enamel finish.

Included Accessories

  • Standard Borosilicate Glass Test Cell with drain

Electrical Requirements

115V 60Hz, Single Phase, 0.4A
220-240V 50/60Hz, Single Phase, 0.2A

Additional Accessories

  • 250-000-33F ASTM 33F Thermometer - Range: –36.5 to +107.5°F 1
  • 250-000-33C ASTM 33C Thermometer - Range: –38 to +42°C
  • 250-000-34F ASTM 34F Thermometer - Range: 77 to 221°F 1
  • 250-000-34C ASTM 34C Thermometer - Range: 25 to 105°C
  • 250-000-35F ASTM 35F Thermometer - Range: 194 to 338°F 1
  • 250-000-35C ASTM 35C Thermometer - Range: 90 to 170°C
  • K10210 Borosilicate Glass Test Cell with drain
  • K10220 Heating-Cooling Tube with platinum element

Alat Laboratorium Umum

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot