PT. Bopana Arga Prima Jaya

sql
Fluke BT521 Advanced Battery Analyzer
Fluke BT521 Advanced Battery Analyzer
Hover to Zoom

03 Feb 2020
United States
1 Unit
IDR CALL

Spesifikasi

Fluke BT521 Advanced Battery Analyzer

Features

  • Key measurements: Internal battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and temperature
  • Sequence measurement mode: Automatic or manual sequence testing of battery strings with automatic measurement storage including voltage, and resistance, eliminating the need to press a button each time a measurement needs to be saved
  • Comprehensive logging: All measured values are automatically captured during testing and can be reviewed on the instrument before downloading for on the-go analysis
  • Optimized user interface: Quick, guided setup ensures you’re capturing the right data every time, and the combined visual and audio feedback cues reduce the risk of measurement confusion
  • Threshold comparison: Configure multiple reference values and thresholds for resistance and voltage. Comparison result feedback after each measurement via visual and verbal cues
  • Ergonomic test leads: Rugged coaxial two pole kelvin test pins with remote SAVE button reduce test time and increase efficiency
  • Intercell strap resistance test and data management: Measures the resistance of the intercell connection between batteries in a string
  • Test probe extenders: Long reach, straight and angled probes for double stacked cells
  • Intelligent test probe set: Integrated LCD display, infrared temperature measurement, verbal audio feedback and captures voltage readings and temperature logging automatically or via integrated save button
  • Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software
  • Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app
  • Wireless communication: For data download and remote display while measuring. Browse and email measurement data via iOS app
  • Battery life: 7.4 V 3000 mAh lithium-ion battery for more than eight hours continuous operation
  • USB port: For fast data download to supplied data analysis and report management application software
  • Highest safety rating in the industry: CAT III 600 V, 1000 V dc maximum rated for safe measurements all around the battery power supply equipment

Voltage and resistance thresholds

Allow you to quickly and easily define upper and lower measurement thresholds or tolerance ranges. During the testing process, measured values are automatically compared to the predefined threshold levels producing a PASS, FAIL or WARN indication after each measurement. A maximum of 10 sets of thresholds can be stored and threshold indications are determined based on the following criterion.

Fluke Battery Management software

Allows you to quickly and easily import data from the battery analyzer to a PC. The measurement data and battery profile information is stored and archived with the Management Software and can be used compare results, switch results between conductance and resistance (requires Software Management software version 1.0.69 or later) readings and perform trend analysis. All measurement data, battery profile and analysis information can be used to easily generate reports.

Applications

  • Maintenance
  • Troubleshooting
  • Performance testing of individual stationary batteries and battery banks used in critical battery backup

Specifications

Battery Resistance/Strap Resistance
Range3 mΩ
30 mΩ
300 mΩ
3000 mΩ
Resolution0.001 mΩ
0.01 mΩ
0.1 mΩ
1 mΩ
Accuracy1% + 8
0.8% + 6
V DC
Range6 V
60 V
600 V
Resolution0.001 V
0.01 V
0.1 V
Accuracy0.09% + 5
V AC (45 to 500 Hz with 800 Hz filter)
Range600 V
Resolution0.1 V
Accuracy2% + 10
Frequency
Range500 Hz
Resolution0.1 Hz
Accuracy0.5% + 8
AC Voltage Ripple (20 KHz Max)
Range600 mV
6000 mV
Resolution0.1 mV
1 mV
Accuracy3% + 20
3% + 10
A DC/A AC (with i410)
Range400 A
Resolution1 A
Accuracy3.5% + 2
Temperature
Range32 to 140°F (0 to 60°C)
Resolution1°C
Accuracy4°F (2°C)
General Specifications
Meter Mode999 records for each measurement position with time stamp
Sequence ModeUp to 100 profiles and 100 profile templates (each profile stores up to 450 batteries) with time stamp
TemperatureOperating: 32 to 104°F (0 to 40°C)
Storage: -4 to 122°F (-20 to 50°C)
Battery charging: 32 to 104°F (0 to 40°C)
Operating HumidityNon-condensing (50 °F [10°C])
≤80% RH (at 50 to 86°F [10 to 30°C])
≤75 % RH (at 86 to 104°F [30 to 40°C])
AltitudeOperating: Sea level to 2000 meters
Storage: Sea level to 12,000 meters
IP RatingIP40
RadioFCC Class A
Vibration RequirementsMIL-PRF-28800F: Class 2
Drop Test Requirements1 meter
Temperature CoefficientsAdd 0.1 x specified accuracy for each °C above 28°C or below 18°C
Safety Compliance600 V CAT III
EMCIEC 61326
Protection Class 2Pollution Degree II
Battery ComplianceUN38.3
UL2054
IEC62133
2G per IEC68-2-26, 25G, and 29
Screen Dimensions3 x 2.2" (7.7 x 5.6 cm)
InterfaceUSB mini
Dimensions9 x 4 x 2" (22 x 10.3 x 5.8 cm)
Weight1.9 lb (850 g)

included with the Fluke BT521

  • Battery Analyzer
  • 4-Wire Test Pin Set
  • Basic Test Lead Set
  • TwistGuard™ Test Leads with Adapter
  • Intelligent Test Probe Set with Extender and Temperature Sensor
  • AC/DC Current Clamp
  • Standard Mini-b USB Cable
  • 2 x Spare Fuses
  • Shoulder Strap
  • Belt Strap
  • Magnetic Hanging Strap
  • 100 x Paper Battery Tags
  • Soft Carrying Case
  • 18 V AC Charger
  • 7.4 V 3000 mAh Lithium-Ion Battery
  • Fluke Battery Management (CD) Containing USB Driver and Manuals in All Languages

Multimeter

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Minta Penawaran
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot